YSLY-OZ/ YSLY-JZ Flexible Control Cable
$0.30 – $15.98Price range: $0.30 through $15.98
The YSLY JZ flexible control cable is designed for medium mechanical stress applications, offering free movement without tensile or forced stress in dry, moist, and wet environments.
The YSLY JZ cable is not suitable for open-air applications where internationally recognized PVC cables are required. Ideal for use as a control cable in industrial machinery, conveyor systems, and industrial plant installations.
The green-yellow earth core is laid in the outer layer.
Complete Technical Specifications
Product Construction
| Component | Specification |
|---|---|
| Conductor | Plain copper flexible wire, Class 5 stranded to DIN VDE 0295 |
| Conductor Material | Electrolytic copper, minimum 99.9% purity |
| Insulation | PVC compound conforming to DIN VDE 0207 |
| Insulation Thickness | Nominal 0.6 mm (varies by conductor size) |
| Filler | Non-hygroscopic compound (for cross-sections above 10 mm²) |
| Outer Sheath | PVC compound conforming to DIN VDE 0281 |
| Sheath Thickness | 0.9 mm minimum (varies by cable diameter) |
| Core Colours | Black cores with white numbering, includes yellow/green earth conductor |
| Sheath Colour | Grey (RAL 7001) |
| Marking | Continuous inkjet printing: YSLY-JZ (section) (year) (traceability code) |
Technical Characteristics & Performance
| Parameter | Specification |
|---|---|
| Nominal Voltage (Uo/U) | 300/500 V |
| Test Voltage | 4000 V |
| Operating Temperature (Fixed Installation) | -40°C to +80°C |
| Operating Temperature (Flexing) | -5°C to +80°C |
| Maximum Short-Circuit Temperature | 150°C (maximum duration: 5 seconds) |
| Minimum Bending Radius (Fixed Installation) | 4 × cable diameter |
| Minimum Bending Radius (Flexing) | 8 × cable diameter |
| Maximum Tensile Stress | 15 N/mm² |
| Flame Retardancy | Self-extinguishing per IEC 60332-1-2 |
| Oil Resistance | Resistant to mineral oils per DIN EN 60811-404 |
Compliance
This product conforms to DIN VDE 0250, DIN VDE 0281, and RoHS Directive 2011/65/EU for restricted substance compliance. For installations in Singapore, ensure compliance with Electricity (Electrical Installations) Regulations administered by the Energy Market Authority.
Feature :
Temperature Range
Flexing -5°C to +80°C
Fixed installation -40°C to +80°C
Nominal Voltage
U₀/U= 300/500 V, Test Voltage 4000V”
Application Guidelines & Recommended Uses
This flexible multicore control cable is engineered for signalling and control installations requiring reliable data transmission in industrial environments. The numbered core identification and flexible Class 5 conductor construction make it ideal for applications demanding frequent movement without tensile stress.
Recommended Applications
Machine tool control systems – CNC machines, lathes, milling equipment
Conveyor belt control circuits – Material handling and production line automation
Building automation systems – HVAC control, lighting management, access control
Industrial machinery wiring – Assembly line equipment, packaging machines
Measurement and control technology – Sensor connections, signal transmission
Electrical panel internal wiring – Distribution boards, control cabinets
Air conditioning and ventilation control – Temperature sensors, damper actuators
Production line automation – Manufacturing process control, quality monitoring
Suitable Installation Environments
- Indoor industrial facilities with controlled environments
- Dry, moist, and wet rooms (not continuously submerged)
- Enclosed electrical cabinets and control panels
- Cable trays and conduit systems with proper support
- Fixed installations with temperatures from -40°C to +80°C
- Flexing applications within -5°C to +80°C temperature range
- Areas with medium mechanical stress and free movement
Installation Restrictions
This product is NOT suitable for:
- Outdoor applications or direct sunlight exposure (UV degradation risk)
- Continuous immersion in water or chemical solutions
- High mechanical stress environments (heavy vehicle traffic, crushing hazards)
- Direct burial underground without protective conduit
- Locations with ambient temperatures exceeding +80°C
- Power transmission applications requiring voltages above 500V
- Areas with forced movements or continuous tensile stress
Other Relevant Products
FAQs
What are power cables?
Power cables are electrical cables designed to carry electrical energy from one point to another. They are used in various applications, including residential, commercial, and industrial settings. Understanding their specifications is crucial for safe and efficient usage.
How to choose cables?
When selecting power cables, consider factors such as voltage rating, current capacity, and environmental conditions. It’s essential to match the cable type to its intended application for optimal performance. Consult our technical datasheets for detailed specifications.
What is cable insulation?
Cable insulation is a protective layer that prevents electrical leakage and protects against environmental factors. It is crucial for ensuring safety and performance. Different materials are used for insulation, depending on the application requirements.
Can I customize orders?
Yes, we offer customizable solutions for power cables to meet your specific needs. You can request variations in length, gauge, and insulation types. Contact our sales team for more details on customization options.
What are standard lengths?
Standard lengths for power cables typically range from 1 meter to 100 meters. However, we can provide longer lengths upon request. Always check the product specifications for available options.